Vapour pressure deficit (VPD) is how hard the air pulls water out of your plants. Set your grow room temperature and humidity to get your VPD in kPa, whether it suits seedlings, vegetative growth or flower, and what to change if it does not. Target ranges: 0.4–0.8 kPa for seedlings and clones, 0.8–1.2 kPa in veg, 1.2–1.5 kPa in flower. Below 0.4 kPa the air is too humid, stomata close and mould risk climbs; above 1.5 kPa the plant loses water faster than its roots can replace it and leaf edges curl upward.
The chart below is calculated at leaf temperature, 2°C below air temperature, which is the usual assumption under LED. A chart built on air temperature alone reads high. Pick your stage (seedling, veg or flower) and the calculator says whether you are on target and which way to move. It also shows your dew point and how far your leaves sit above it: a thin margin means moisture can condense on leaves and buds, which is where bud rot and powdery mildew start. The chart can be downloaded as a printable PNG for your tent.
| Air temp °F | 30% | 35% | 40% | 45% | 50% | 55% | 60% | 65% | 70% | 75% | 80% |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 64°F | 1.18 | 1.08 | 0.98 | 0.88 | 0.77 | 0.67 | 0.57 | 0.47 | 0.37 | 0.27 | 0.16 |
| 66°F | 1.27 | 1.16 | 1.05 | 0.94 | 0.83 | 0.72 | 0.61 | 0.51 | 0.40 | 0.29 | 0.18 |
| 68°F | 1.36 | 1.25 | 1.13 | 1.01 | 0.89 | 0.78 | 0.66 | 0.54 | 0.43 | 0.31 | 0.19 |
| 70°F | 1.46 | 1.34 | 1.21 | 1.09 | 0.96 | 0.84 | 0.71 | 0.59 | 0.46 | 0.33 | 0.21 |
| 72°F | 1.57 | 1.43 | 1.30 | 1.16 | 1.03 | 0.90 | 0.76 | 0.63 | 0.49 | 0.36 | 0.23 |
| 74°F | 1.68 | 1.54 | 1.39 | 1.25 | 1.11 | 0.96 | 0.82 | 0.68 | 0.53 | 0.39 | 0.25 |
| 76°F | 1.80 | 1.64 | 1.49 | 1.34 | 1.18 | 1.03 | 0.88 | 0.72 | 0.57 | 0.42 | 0.26 |
| 78°F | 1.92 | 1.76 | 1.60 | 1.43 | 1.27 | 1.10 | 0.94 | 0.78 | 0.61 | 0.45 | 0.29 |
| 80°F | 2.06 | 1.88 | 1.71 | 1.53 | 1.36 | 1.18 | 1.01 | 0.83 | 0.66 | 0.48 | 0.31 |
| 82°F | 2.20 | 2.01 | 1.82 | 1.64 | 1.45 | 1.27 | 1.08 | 0.89 | 0.71 | 0.52 | 0.33 |
| 84°F | 2.35 | 2.15 | 1.95 | 1.75 | 1.55 | 1.35 | 1.15 | 0.96 | 0.76 | 0.56 | 0.36 |
| 86°F | 2.51 | 2.29 | 2.08 | 1.87 | 1.66 | 1.45 | 1.23 | 1.02 | 0.81 | 0.60 | 0.39 |
| 88°F | 2.68 | 2.45 | 2.22 | 2.00 | 1.77 | 1.54 | 1.32 | 1.09 | 0.87 | 0.64 | 0.41 |
| 90°F | 2.85 | 2.61 | 2.37 | 2.13 | 1.89 | 1.65 | 1.41 | 1.17 | 0.93 | 0.69 | 0.45 |
| Air temp °C | 30% | 35% | 40% | 45% | 50% | 55% | 60% | 65% | 70% | 75% | 80% |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 18°C | 1.20 | 1.10 | 0.99 | 0.89 | 0.79 | 0.68 | 0.58 | 0.48 | 0.37 | 0.27 | 0.17 |
| 19°C | 1.28 | 1.17 | 1.06 | 0.95 | 0.84 | 0.73 | 0.62 | 0.51 | 0.40 | 0.29 | 0.18 |
| 20°C | 1.36 | 1.25 | 1.13 | 1.01 | 0.89 | 0.78 | 0.66 | 0.54 | 0.43 | 0.31 | 0.19 |
| 21°C | 1.45 | 1.33 | 1.20 | 1.08 | 0.95 | 0.83 | 0.71 | 0.58 | 0.46 | 0.33 | 0.21 |
| 22°C | 1.55 | 1.41 | 1.28 | 1.15 | 1.02 | 0.88 | 0.75 | 0.62 | 0.49 | 0.36 | 0.22 |
| 23°C | 1.64 | 1.50 | 1.36 | 1.22 | 1.08 | 0.94 | 0.80 | 0.66 | 0.52 | 0.38 | 0.24 |
| 24°C | 1.75 | 1.60 | 1.45 | 1.30 | 1.15 | 1.00 | 0.85 | 0.70 | 0.56 | 0.41 | 0.26 |
| 25°C | 1.86 | 1.70 | 1.54 | 1.38 | 1.23 | 1.07 | 0.91 | 0.75 | 0.59 | 0.43 | 0.28 |
| 26°C | 1.98 | 1.81 | 1.64 | 1.47 | 1.30 | 1.14 | 0.97 | 0.80 | 0.63 | 0.46 | 0.29 |
| 27°C | 2.10 | 1.92 | 1.74 | 1.56 | 1.39 | 1.21 | 1.03 | 0.85 | 0.67 | 0.49 | 0.32 |
| 28°C | 2.23 | 2.04 | 1.85 | 1.66 | 1.47 | 1.28 | 1.09 | 0.90 | 0.72 | 0.53 | 0.34 |
| 29°C | 2.36 | 2.16 | 1.96 | 1.76 | 1.56 | 1.36 | 1.16 | 0.96 | 0.76 | 0.56 | 0.36 |
| 30°C | 2.51 | 2.29 | 2.08 | 1.87 | 1.66 | 1.45 | 1.23 | 1.02 | 0.81 | 0.60 | 0.39 |
| 31°C | 2.66 | 2.43 | 2.21 | 1.98 | 1.76 | 1.53 | 1.31 | 1.09 | 0.86 | 0.64 | 0.41 |
| 32°C | 2.82 | 2.58 | 2.34 | 2.10 | 1.87 | 1.63 | 1.39 | 1.15 | 0.91 | 0.68 | 0.44 |
Roughly 0.4–0.8 kPa for seedlings and clones, 0.8–1.2 kPa through vegetative growth, and 1.2–1.5 kPa in flower. Below 0.4 kPa transpiration stalls; above 1.5 kPa the plant loses water faster than the roots can replace it.
Saturation vapour pressure at leaf temperature minus the actual vapour pressure of the air. This calculator uses the Tetens equation, subtracts a leaf-temperature offset (2°C under LED by default), and multiplies air saturation by relative humidity.
Leaf temperature. A transpiring canopy under LED sits about 2°C below air temperature, so an air-temperature chart reads high. Set the offset to 0 for the air-temperature figure.
Too low and stomata close, nutrient uptake slows and mould risk climbs. Too high and leaf edges curl upward as the plant loses water faster than the roots supply it, and growth stalls.
Watch humidity more than the VPD number at night. When the lights go off the leaves cool, relative humidity climbs, and the gap between leaf temperature and dew point shrinks. If the leaves reach the dew point, water condenses on them, which is where bud rot and powdery mildew start, especially in late flower. Keep the dehumidifier running through the dark period and avoid a big temperature drop at lights-off.
Dew point is the temperature at which the air’s moisture condenses into water. A leaf only a degree or two above the dew point can collect moisture as conditions shift, so a comfortable margin protects dense buds from mould.
Veridian Grow — indoor cannabis growing tools & guides